The Hercules cameras are UVC compliant, so they should work with the DirectShow Interface IAMCameraControl. You can set the focus to a specific value, and use the flags to set that you do not want it to be automatic. You can use IAMCameraControl::Get
to poll the current state, because not all cameras do support turning off the focus.
IAMCameraControl *pCameraControl;
HRESULT hr;
hr = pFilter->QueryInterface(IID_IAMCameraControl, (void **)&pCameraControl);
if (hr == S_OK) {
long defaultFocusValue;
hr = pCameraControl->GetRange(CameraControl_Focus,
NULL, // min
NULL, // max
NULL, // minstep
&defaultFocusValue, // default
NULL); // capflags
hr = pCameraControl->Set(CameraControl_Focus, // property
defaultFocusValue, // value
CameraControl_Flags_Manual);
}
Focus has a range which is defined by each camera separately, so you should query it as shown to find the default value and the min, max if you want.
In this example the pFilter
is a pointer to the input filter that you have from DirectShow. You can get it by enumerating the devices and finding the one you want.